CMP Glands - E2FU Ex Flameproof Universal Cable Gland (Ex d, Ex e, Ex nR)

CMP Glands - E2FU Ex Flameproof Cable Gland for Lead Covered, Lead Sheathed and Armoured Cables

CMP E2FU Universal Cable Glands for Hazardous Areas - Triple Certified (Ex d, Ex e, Ex nR)

CMP E2FU Tri-Star Cable Glands are Triple Certified Flameproof Ex d, Increased Safety Ex e and Restricted Breathing Ex nR suitable for Indoor and Outdoor use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas.

CMP E2FU Flameproof Cable Glands - Triple Certified (Ex d, Ex e, Ex nR) - Features

This cable gland ensures a Flameproof seal on the cable inner bedding. Also the gas tight seal has been tested to prove compatibility with Restricted Breathing equipment.

The E2FU cable gland allows mechanical cable retention and earth continuity via the cable armour termination, together with earth bonding of the inner Lead Covering or Lead Sheath.

Maximum control over the pressure applied to the cable inner lead covering is achieved through separate tightening actions for the inner Displacement Seal and the Armour Termination. This feature also allows the effectiveness of the gas tight seal to be tested.

Remote make off of the CMP E2FU Gland is facilitated by a detachable universal armour cone and AnyWay clamping ring arrangement. This feature also enables the cable to be disconnected from the equipment.

This CMP Cable Gland provides an environmental / load retention seal on the outer sheath of the cable.

All CMP E2FU Cable Glands are EMC Tested.

The CMP E2FU Tri-Star Cable Gland is suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, Zone 21 & Zone 22 subject to the prevailing code of practice for selection and installation being observed, e.g. IEC 60079-14.

Note: Deluge Proof version available, ferrule colour coded "white" for ease of identification.

Note: Stepped Cone is suitable for SWA cables, Grooved Cone is suitable for all other approved armoured cables

CMP E2FU Flameproof Cable Glands (Ex d, Ex e, Ex nR) Triple Certified Ex Gland - Metric

Cable Gland Size

Available Entry Threads "C"

Min Thread Length "E"

Lead Sheath Diameter "A"

Overall Cable Diameter "B"

Across Flats "D"

Across Corners "D"

Prot. Length "F"

Standard

Option

Min

Max

Min

Max

Max

Max

Metric

NPT

NPT

20S/16

M20

1/2"

3/4"

15.0

3.1

8.6

6.1

13.2

24.0

25.9

58.5

20S

M20

1/2"

3/4"

15.0

6.1

11.6

9.5

15.9

24.0

25.9

58.5

20

M20

1/2"

3/4"

15.0

6.5

13.9

12.5

20.9

30.5

32.9

60.5

25S

M25

3/4"

1"

15.0

11.1

19.9

14.0

22.0

37.5

40.5

67.5

25

M25

3/4"

1"

15.0

11.1

19.9

18.2

26.2

37.5

40.5

67.5

32

M32

1"

1 1/4"

15.0

17.0

26.2

23.7

33.9

46.0

49.7

69.5

40

M40

1 1/4"

1 1/2"

15.0

22.0

32.1

27.9

40.4

55.0

59.4

78.0

50S

M50

1 1/2"

2"

15.0

29.5

38.1

35.2

46.7

60.0

64.8

75.5

50

M50

2"

2 1/2"

15.0

35.6

44.0

40.4

53.1

70.0

75.6

80.5

63S

M63

2"

2 1/2"

15.0

40.1

49.9

45.6

59.4

75.0

81.0

91.5

63

M63

2 1/2"

3"

15.0

47.2

55.9

54.6

65.9

80.0

86.4

92.0

75S

M75

2 1/2"

3"

15.0

52.8

61.9

59.0

72.1

89.0

96.1

99.0

75

M75

3"

3 1/2"

15.0

59.1

67.9

66.7

78.5

99.0

106.9

102.0

90

M90

3 1/2"

4"

15.0

66.6

79.9

76.2

90.4

114.0

123.1

120.0

100

M100

4"

-

15.0

76.0

90.9

86.1

101.5

123.0

132.8

148.0

115

M115

-

-

15.0

86.0

97.9

101.5

110.3

133.4

144.1

169.0

130

M130

-

-

15.0

97.0

114.9

114.2

123.3

146.1

157.8

183.0

Dimensions are shown in millimetres unless otherwise stated

 

Cable Gland Size

Armour Range +

Ordering Reference (Brass Metric) #

PVC Shroud Ref*

Cable Gland Weight (Kgs)

Grooved Cone

Stepped Cone

Min

Max

Min

Max

20S/16

0.0

1.0

0.9

1.0

20S16E2FU1RA

PVC04

0.163

20S

0.0

1.0

0.9

1.25

20SE2FU1RA

PVC04

0.163

20

0.0

1.0

0.9

1.25

20E2FU1RA

PVC06

0.217

25S

0.0

1.0

1.25

1.6

25SE2FU1RA

PVC09

0.345

25

0.0

1.0

1.25

1.6

25E2FU1RA

PVC09

0.345

32

0.0

1.0

1.6

2.0

32E2FU1RA

PVC11

0.484

40

0.0

1.0

1.6

2.0

40E2FU1RA

PVC15

0.700

50S

0.0

1.0

2.0

2.5

50SE2FU1RA

PVC18

0.800

50

0.0

1.0

2.0

2.5

50E1FU1RA

PVC21

0.830

63S

0.0

1.0

2.0

2.5

63SE2FU1RA

PVC23

1.415

63

0.0

1.0

2.0

2.5

63E2FU1RA

PVC25

1.514

75S

0.0

1.0

2.0

2.5

75SE2FU1RA

PVC28

2.199

75

0.0

1.0

2.5

3.0

75E2FU1RA

PVC30

2.770

90

0.0

1.6

3.0

3.5

90E2FU1RA

PVC32

4.350

100

0.0

1.6

3.15

4.0

100E2FU1RA

LSF33

4.750

115

0.0

1.6

3.15

4.0

115E2FU1RA

LSF34

7.300

130

0.0

1.6

3.15

4.0

130E2FU1RA

LSF35

8.600

Dimensions are shown in millimetres unless otherwise stated

CMP E2FU Flameproof Cable Glands (Ex d, Ex e, Ex nR) Triple Certified Ex Gland - Imperial

Cable Gland Size

Available Entry Threads "C"

Min Thread Length "E"

Lead Sheath Diameter "A"

Overall Cable Diameter "B"

Across Flats "D"

Across Corners "D"

Prot. Length "F"

Standard

Option

Min

Max

Min

Max

Max

Max

Metric

NPT

NPT

20S/16

M20

1/2"

3/4"

0.591

0.122

0.339

0.240

0.519

0.945

1.020

2.303

20S

M20

1/2"

3/4"

0.591

0.240

0.457

0.374

0.626

0.945

1.020

2.303

20

M20

1/2"

3/4"

0.591

0.256

0.547

0.492

0.823

1.201

1.295

2.382

25S

M25

3/4"

1"

0.591

0.437

0.783

0.551

0.866

1.476

1.594

2.657

25

M25

3/4"

1"

0.591

0.437

0.783

0.717

1.031

1.476

1.594

2.657

32

M32

1"

1 1/4"

0.591

0.669

1.031

0.933

1.335

1.811

1.957

2.736

40

M40

1 1/4"

1 1/2"

0.591

0.866

1.264

1.098

1.591

2.165

2.339

3.071

50S

M50

1 1/2"

2"

0.591

1.161

1.500

1.386

1.839

2.362

2.551

2.972

50

M50

2"

2 1/2"

0.591

1.402

1.732

1.591

2.091

2.756

2.976

3.169

63S

M63

2"

2 1/2"

0.591

1.579

1.965

1.795

2.339

2.953

3.189

3.602

63

M63

2 1/2"

3"

0.591

1.858

2.201

2.150

2.594

3.150

3.402

3.622

75S

M75

2 1/2"

3"

0.591

2.079

2.437

2.323

2.839

3.504

3.783

3.898

75

M75

3"

3 1/2"

0.591

2.327

2.673

2.626

3.091

3.898

4.209

4.016

90

M90

3 1/2"

4"

0.591

2.622

3.146

3.000

3.559

4.488

4.846

4.724

100

M100

4"

-

0.591

2.992

3.579

3.390

3.996

4.843

5.228

5.827

115

M115

-

-

0.591

3.386

3.854

3.996

4.343

5.252

5.673

6.654

130

M130

-

-

0.591

3.819

4.524

4.496

4.854

5.752

6.213

7.205

Dimensions are shown in inches unless otherwise stated

 

Cable Gland Size

Armour Range +

Ordering Reference (Brass Metric) #

PVC Shroud Ref*

Cable Gland Weight (Ozs)

Grooved Cone

Stepped Cone

Min

Max

Min

Max

20S/16

0.000

0.039

0.035

0.039

20S16E2FU1RA

PVC04

5.75

20S

0.000

0.039

0.035

0.049

20SE2FU1RA

PVC04

5.75

20

0.000

0.039

0.035

0.049

20E2FU1RA

PVC06

7.65

25S

0.000

0.039

0.049

0.063

25SE2FU1RA

PVC09

12.17

25

0.000

0.039

0.049

0.063

25E2FU1RA

PVC09

12.17

32

0.000

0.039

0.063

0.079

32E2FU1RA

PVC11

17.07

40

0.000

0.039

0.063

0.079

40E2FU1RA

PVC15

24.69

50S

0.000

0.039

0.079

0.098

50SE2FU1RA

PVC18

28.22

50

0.000

0.039

0.079

0.098

50E1FU1RA

PVC21

29.28

63S

0.000

0.039

0.079

0.098

63SE2FU1RA

PVC23

49.91

63

0.000

0.039

0.079

0.098

63E2FU1RA

PVC25

53.40

75S

0.000

0.039

0.079

0.098

75SE2FU1RA

PVC28

77.57

75

0.000

0.039

0.098

0.118

75E2FU1RA

PVC30

97.71

90

0.000

0.063

0.118

0.138

90E2FU1RA

PVC32

153.44

100

0.000

0.063

0.124

0.157

100E2FU1RA

LSF33

167.55

115

0.000

0.063

0.124

0.157

115E2FU1RA

LSF34

257.50

130

0.000

0.063

0.124

0.157

130E2FU1RA

LSF35

303.36

Dimensions are shown in inches unless otherwise stated

NOTE: *CMP SOLO LSF Halogen Free Shrouds also available on request. + Alternative armour clamping range available for non-standard armour sizes. # Other thread forms, materials and finishes are available. IEC Ex, ATEX & CSA hazardous area certification marking included as standard. Please consult CMP for any other requirements.

CMP E2FU Flameproof Cable Glands (Ex d, Ex e, Ex nR) Triple Certified Ex Gland - Technical Data

Type

E2FU Tri-Star

Design Specification

BS 6121:Part 1:1989, EN 50262:1999

ATEX Certification Detail

SIRA06ATEX1097X, SIRA07ATEX4326X

ATEX Code of Protection Category

ATEX Ex II 2 GD, Ex d IIC, Ex e II, Ex tD A21 IP66, ATEX Ex II 3 G Ex nR II

ATEX Compliance Standards

EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-15, IEC 61241-0, EN 61241-1

IEC Ex Certification Detail

IECEx SIR 06.0043X

IEC Ex Code of Protection Category

Ex d IIC, Ex e II, Ex nR II, Ex tD A21 IP66, Ex d I,
Ex e I

IEC Ex Compliance Standards

IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 60079-15, IEC 61241-0, IEC 61241-1

Continuous Operating Temperature

-60°C to +130°C

Ingress Protection Rating

IP66, IP67, IP68 #

Cable Gland Material

Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium

Seal Material

CMP SOLO LSF Thermoplastic Elastomer

Cable Type

Lead Sheathed & Single Wire Armour (LC/SWA), Lead Sheathed & Aluminium Wire Armour (LC/AWA), Lead Sheathed & Wire Braid Armour (LC/SWB), Lead Sheathed & Pliable Wire Armour (LC/PWA), Lead Sheathed & Steel Tape Armour (LC/STA), Lead Sheathed & Aluminium Strip Armour (LC/ASA)

Armour Clamping

Reversible Armour Cone & AnyWay Universal Clamping Ring

Sealing Technique

CMP Inner Displacement Seal & Unique CMP "LRS" TM Outer Load Retention Seal

Sealing Area(s)

Cable Inner Lead Covering & Cable Outer Sheath

Accessories

Adaptor/Reducer, Earth Tag, Locknut, Serrated Washer, Entry Thread Seal, Shroud

# IP66 as standard, IP67/IP68 available on request. Deluge Proof when fitted with optional CMP O-ring in the cable gland body joint.

Note: Ingress Protection and Deluge Protection are essentially different and should not be confused with each other.

If Tape Armour is to be used please contact CMP for advice.

CMP E2FU Flameproof Cable Glands (Ex d, Ex e, Ex nR) Triple Certified Ex Gland - Approvals Data

CSA Approval Certificate No

1310517

CSA Code of Protection Category

Ex d IIC; Ex e II

CSA Compliance Standards

CAN/CSA-C22.2 No 0-M91, CAN/CSA-C22.2 No 18-04, CAN/CSA-C22.2 No 25-1966, CAN/CSA-C22.2 No 30-M1986, CAN/CSA-C22.2 No 174-M1984, CAN/CSA-C22.2 No 94-M91, CAN/CSA-E60079-0:07, CAN/CSA-E60079-7:07, CAN/CSA-E60079-1:07

GOST R Certificate Number

POCC GB.HO06.B00207

GOST R Code of Protection Category

Ex d IIC / Ex e II / DIP A21

GOST R Compliance Standards

ГOCT P 52350.0-2005, ГOCT P 52350.1-2005,
ГOCT P 52350.7-2005, ГOCT MЭK 61241-1-1-99

GOST GGTN Permit

PPC 00-40706

GOST K Certificate Number

KZ 75000361 01 01 14761

RoK Permit For Use Number

19-02-UL-1957

Lloyds Approval No

01/00172

DNV Approval No.

E-10496

ABS Approval No.

01-LD234401A/2-PDA

INMETRO Approval Certificate Number.

MC, AEX-7618-X

INMETRO Code of Protection Category

BR - Ex d IIC / BR - Ex e II / IP66W

INMETRO Compliance Standards

ABNT NBR IEC 60079-0:2006, ABNT NBR IEC 60079-1:2007, IEC 60079-7:2001 e ANBT NBR IEC 60529:2005

NEPSI Certificate Number

GYJ081070

NEPSI Code of Protection Category

Ex d IIC, Ex e II, Ex nR II, DIP A21 TA

NEPSI Compliance Standards

GB3836.1/2/3, GB3836.8-2003, GB12476.1-2000

RETIE Approval Number

03866